1. Accurate AC digital clamp meter for leakage current measurement.
2. 10μA high resolution on 40mA range.
3. Shield transformer jaws to minimize the effect of external stray magnetic field.
4. Large jaw with 30 mm diameter.
5. Five Ranges (40mA, 400mA, 4A, 40A, 60A) for all application.
6. A filter circuit is designed to eliminate the effect of high frequency noise and harmonics for AC current measurement.
7. Large 3 3/4 digits LCD
8. Fast bargraph display (20 times/sec.) for transient observation.
9. Continuity and frequency measurements.
10.Max/Min, Data Hold functions, and Relative Measurement.
11.600V overload protection for ohm measurement.
12.Easy single rotary switch for any function selection.
or
DCM-040
or
Specifications:
Specifications:
Specifications(23°C±5°C)
AC Current:
Accuracy Remarks
Range Resolution 50/60 Hz Wide
(40 - 1KHz)
40mA 10μA ±1.0%±3dgts ±2.0%±5dgts
400mA 100μA ±1.0%±3dgts ±2.0%±5dgts
4A 1mA ±1.0%±3dgts ±2.0%±5dgts
40A 10mA ±1.0%±3dgts ±2.0%±5dgts
60A(0-50A) 100mA ±1.5%±3dgts ±3.0%±5dgts
60A(50 - 60A) (1) 100mA ±3.0%±5dgts ±3.5%±5dgts
1)Though the meter can display up to 400A, it is not calibrated beyond 60A
AC Voltage:(Input Impedance: 10MΩ)
AC Voltage:(Input Impedance: 10MΩ)
Accuracy Overload Protection
Range Resolution 50/60 Hz 40 - 1KHz
400V 0.1V ±1.5%±2dgts ±2.0%±4dgts AC 800V
Resistance (Ω) and Continuity:
Resistance (Ω) and Continuity:
(open voltage 0.4V)
Range Resolution Accuracy Beeping OL Protection
40-400Ω 0.1Ω
±1.0%±2dgts < 38.0 ΩAC 600 V
General Specification
General Specification Conductor Size: 30mm max. (approx.)